86exporter.com Home       Products Catalog      Suppliers Catalog      Log In        Sign up
      About Us
      Profile
      Products
      Contact Us


Getein Biotechnology Co., Ltd

Products >> Cardiac Troponin I Fast Test Kit

Cardiac Troponin I Fast Test Kit

Build Your Online Product Catalogs?



Description
Product Name: Cardiac Troponin I Fast Test Kit
Supply Ability: 100
Related proudcts rapid diagnostic tes,
Specifications medical diagnostic rapid test kit,medical equipment
Price Term: T/T L/C
Port of loading: Shanghai
Minimum Order 1
Unit Price:

Intended Use:



Cardiac Troponin I Fast Test Kit applies colloidal gold immunochromatography to ***ect cardiac Troponin I

(cTnI) in serum and plasma samples semi-quantitatively or quantitatively. This test is used as an aid in the

diagnosis of Myocardial Infarction such as Acute Myocardial Infarction, Unstable Angina, Acute Myocarditis,

and Acute Coronary Syndrome.



Principle of the Procedure:



The test kit contains two high specific and sensitive anti-human cardiac Troponin I monoclonal antibodies:

one gold-labelled and coated on the polyester film, the other biotinylated and fixed on the test line of the

product. The antibodies form sandwich complexes with any cTnI that is present in the blood sample. The

sample passes through the ***ection zone, in which the cTnI sandwich complexes gather along a line,

appearing as a purplish red streak (the test or signal line). Excess gold-labelled antibodies gather along

the control line, signalling visually that the test is valid. The intensity of the test line increases in proportion

to the cardiac Troponin I concentration.



Test Procedure:

1. Please read the manual carefully before testing, restore the samples and the test card to room temperature

and number the samples.

2. Remove the test card from bag, and use it within 1 hour. (The test card should be used as quickly as

possible once the bag is opened, especially if the room temperature is over 30 °C and the humidity is over 60%).

3. Put the test card on a clean table, horizontally layed and tagged.

4. Vertically dropping 120 μl or 3 to 4 drops of samples to the sample port on the test card.

5. Referring to the standard colorimetric card, get the semi-quantitative result by eye, or read the quantitative

result with the matching equipment. The result must be read within 10~30 mins.



Warnings and Precautions:



1. Pipettes can be used for one specimen only in order to avoid cross-contamination.

2. The best te

Contact Us
Company: Getein Biotechnology Co., Ltd
Contact: Ms. Fiona Chen
Address: No.9 Bofu Road,Luhe District,Nanjing,211505,China
Postcode: 211505
Tel: +86-25-68576663
Fax: +86-25-68576663
E-mail:         


Copyright© Getein Biotechnology Co., Ltd All Rights Reserved.
Tel : +86-25-68576663 Fax : +86-25-68576663
Powered by 86exporter.com